Label

ProFume

Sulfuryl Fluoride (2)
Group 8C Insecticide
1015-79
N/A
N/A

LABEL

Label - English

SDS

MSDS/SDS - English

SUPPLEMENTAL LABELS

  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (AL)
  • For Use on Treated Walnuts for Processing and Packaging (CA)
  • For Use on Sunflower Seeds for Planting for Control of Postharvest Pests (CA)
  • Funigation of Cocoa Bean for Control of Postharvest Insects (DE)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (IL)
  • Fumigation of Cocoa Bean for Control of Postharvest Insect Pests (MD)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (MD)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (MS)
  • For Fumigation of Non-Edible Commodities and for Fumigation of Non-Edible Commodities Using Quarantine/Regulatory Treatment Schedules (NC)
  • Fumigation of Cocoa Bean for Control of Postharvest Insect Pests (NJ)
  • Fumigation of Cocoa Bean for Control of Postharvest Insect Pests (PA)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (SC)
  • For Use on Cocoa Beans for Control of Postharvest Insect Pests (VA)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules (VA)
  • Fumigation of Non-Edible Commodities and Use of Quarantine/Regulatory Treatment Schedules for Control of Wood-Infesting Insects (WA)

WP/S&T

Wear splash resistant goggles or full face shield when handling the liquid product during introduction of fumigant or when working around any lines containing fumigant under pressure. Do not wear gloves or rubber boots. Do not reuse clothing or shoes that have become contaminated with liquid ProFume until thoroughly aerated. Wear loose fitting or well-ventilated long-sleeve shirt, long pants, shoes and socks. Respiratory Protection: If the concentration of ProFume in the fumigated area as measured by a detection device with sufficient sensitivity [Limit of Detection (LOD) ≤ 1 ppm] such as an INTERSCAN gas analyzer [Model GF 1900] or MIRAN vapor analyzer [SapphlRe] does not exceed 1 ppm, no respiratory protection is required. When this concentration is exceeded or when the concentration of ProFume is unknown, all persons in these areas must wear a NIOSH or MSHA approved positive pressure self-contained breathing apparatus (SCBA, not SCUBA), approval number prefix TC- 19C, or combination air-supplied/SCBA respirator such as manufactured by Draeger, Ranger, Survivair, Scott, or MSA. This SCBA must be on site and operational before fumigation. Before using any make or brand of SCBA, learn how to use it correctly. Determine that it is in good working order, has an adequate air supply for the job at hand, fits properly, and provides an adequate seal around the face.

Storing indoors in occupied areas in buildings is not recommended. Store in an adequately dry, cool, well ventilated secured and locked area. Post as a pesticide storage area. All cylinders should be stored in an upright position with safety caps and protective bonnets securely in place.

Sara Title III

Hazardous Ingredient Cas # Percent EHS TPQ TRQ of Ingredient
Sulfuryl fluoride 2699-79-8 99.8 NOL STD
1,2-Dichloroethane 107-06-2 0.04 NOL STD
[Balance] 0.16
Sulfuryl fluoride
Cas # 2699-79-8
Percent 99.8
EHS TPQ NOL
TRQ of Ingredient STD
1,2-Dichloroethane
Cas # 107-06-2
Percent 0.04
EHS TPQ NOL
TRQ of Ingredient STD
[Balance]
Cas #
Percent 0.16
EHS TPQ
TRQ of Ingredient

STATE RESTRICTIONS

Restricted
Not Restricted
State Updated Restriction Status
Alaska 06/13/2019 Not Restricted
Alabama 06/13/2019 Not Restricted
Arkansas 06/13/2019 Not Restricted
Arizona 06/13/2019 Not Restricted
California 06/13/2019 Not Restricted
Colorado 06/13/2019 Not Restricted
Connecticut 06/13/2019 Not Restricted
Delaware 06/13/2019 Not Restricted
Florida 06/13/2019 Not Restricted
Georgia 06/13/2019 Not Restricted
Hawaii 06/13/2019 Not Restricted
Iowa 06/13/2019 Not Restricted
Idaho 06/13/2019 Not Restricted
Illinois 06/13/2019 Not Restricted
Indiana 06/13/2019 Not Restricted
Kansas 06/13/2019 Not Restricted
Kentucky 06/13/2019 Not Restricted
Louisiana 06/13/2019 Not Restricted
Massachusetts 06/13/2019 Not Restricted
Maryland 06/13/2019 Not Restricted
Maine 06/13/2019 Not Restricted
Michigan 06/13/2019 Not Restricted
Minnesota 06/13/2019 Not Restricted
Missouri 06/13/2019 Not Restricted
Mississippi 06/13/2019 Not Restricted
Montana 06/13/2019 Not Restricted
North Carolina 06/13/2019 Not Restricted
North Dakota 06/13/2019 Not Restricted
Nebraska 06/13/2019 Not Restricted
New Hampshire 06/13/2019 Not Restricted
New Jersey 06/13/2019 Not Restricted
New Mexico 06/13/2019 Not Restricted
Nevada 06/13/2019 Not Restricted
New York 06/13/2019 Not Restricted
Ohio 06/13/2019 Not Restricted
Oklahoma 06/13/2019 Not Restricted
Oregon 06/13/2019 Not Restricted
Pennsylvania 06/13/2019 Not Restricted
Rhode Island 06/13/2019 Not Restricted
South Carolina 06/13/2019 Not Restricted
South Dakota 06/13/2019 Not Restricted
Tennessee 06/13/2019 Not Restricted
Texas 06/13/2019 Not Restricted
Utah 06/13/2019 Not Restricted
Virginia 06/13/2019 Not Restricted
Vermont 06/13/2019 Not Restricted
Washington 06/13/2019 Not Restricted
Wisconsin 06/13/2019 Not Restricted
West Virginia 06/13/2019 Not Restricted
Wyoming 06/13/2019 Not Restricted

PRODUCT APPLICATION

GAS FUMIGANT

  • Gas Fumigant
    • 1500 Ct
    • 128 G / Cu_M