Label

Termidor HP II

Fipronil (24)
Group 2B Insecticide
N/A
7969-400
N/A
N/A

LABEL

Label - English

SDS

MSDS/SDS - English
MSDS/SDS - Spanish

WP/S&T

Applicators and other handlers must wear: Long-sleeved shirt and long pants Shoes plus socks Waterproof gloves, made of barrier laminate, butyl rubber ≥ 14 mils, nitrile rubber ≥ 14 mils, neoprene rubber ≥ 14 mils, natural rubber* ≥ 14 mils, polyethylene, polyvinyl chloride (PVC) ≥ 14 mils, or viton ≥ 14 mils * Includes natural rubber blends and laminates When working in a non-ventilated space, including but not limited to crawl spaces and basements, all pesticide handlers must wear: A dust/mist filtering respirator MSHA/NIOSH approval number prefix TC-21C), or a NIOSH-approved respirator with any N, R, P, or HE filter When working in a non-ventilated space, including but not limited to crawl spaces and basements or when applying termiticide by rodding or sub-slab injection, all pesticide handlers must wear: Protective eyewear (goggles, a face shield, or safety glasses with front, brow, and temple protection)

Store unused product in original container only, out of reach of children and animals.

Sara Title III

Hazardous Ingredient Cas # Percent EHS TPQ TRQ of Ingredient
[Fipronil] 120068-37-3 8.73 NOL
[Fipronil]
Cas # 120068-37-3
Percent 8.73
EHS TPQ NOL
TRQ of Ingredient

STATE RESTRICTIONS

Restricted
Not Restricted
State Updated Restriction Status
Alabama 06/17/2019 Not Restricted
Arkansas 06/17/2019 Not Restricted
Arizona 06/17/2019 Not Restricted
Colorado 06/17/2019 Not Restricted
Connecticut 06/17/2019 Not Restricted
Delaware 06/17/2019 Not Restricted
Florida 06/17/2019 Not Restricted
Georgia 06/17/2019 Not Restricted
Hawaii 06/17/2019 Not Restricted
Iowa 06/17/2019 Not Restricted
Idaho 06/17/2019 Not Restricted
Illinois 06/17/2019 Not Restricted
Indiana 06/17/2019 Not Restricted
Kansas 06/17/2019 Not Restricted
Kentucky 06/17/2019 Not Restricted
Louisiana 06/17/2019 Not Restricted
Massachusetts 06/17/2019 Not Restricted
Michigan 06/17/2019 Not Restricted
Minnesota 06/17/2019 Not Restricted
Missouri 06/17/2019 Not Restricted
Mississippi 06/17/2019 Not Restricted
Montana 06/17/2019 Not Restricted
North Carolina 06/17/2019 Not Restricted
North Dakota 06/17/2019 Not Restricted
Nebraska 06/17/2019 Not Restricted
New Hampshire 06/17/2019 Not Restricted
New Jersey 06/17/2019 Not Restricted
New Mexico 06/17/2019 Not Restricted
Nevada 06/17/2019 Not Restricted
Ohio 06/17/2019 Not Restricted
Oregon 06/17/2019 Not Restricted
Pennsylvania 06/17/2019 Not Restricted
Rhode Island 06/17/2019 Not Restricted
South Carolina 06/17/2019 Not Restricted
South Dakota 06/17/2019 Not Restricted
Tennessee 06/17/2019 Not Restricted
Texas 06/17/2019 Not Restricted
Utah 06/17/2019 Not Restricted
Virginia 06/17/2019 Not Restricted
Vermont 06/17/2019 Not Restricted
Washington 06/17/2019 Not Restricted
Wisconsin 06/17/2019 Not Restricted
West Virginia 06/17/2019 Not Restricted
Wyoming 06/17/2019 Not Restricted
Alaska 06/17/2019 Restricted
California 06/17/2019 Restricted
Maryland 06/17/2019 Restricted
Maine 06/17/2019 Restricted
New York 06/17/2019 Restricted
Oklahoma 06/17/2019 Restricted

PRODUCT APPLICATION

EXTERIOR PERIMETER TREATMENT

  • Sub-Slab Injection
    • 2 Gal / 10 Linear_Ft / Ft_Of_Depth
  • Basement And Crawl Space Construction
    • 1 Gal / Sq_Ft

TREATMENT OF STRUCTURES WITH WELLS OR CISTERNS

  • Treatment Of Structures With Wells Or Cisterns
    • 2 Gal Finished Dilution / 10 Linear_Ft / Ft
    • 1 Gal / Cu_Ft

SUB-SLAB INJECTION

  • Sub-Slab Injection
    • 2 Gal / 10 Linear_Ft / Ft_Of_Depth

LOCALIZED INTERIOR TREATMENT

  • Shower Pan Drains
    • 1 - 4 Gal
  • Hollow Block Foundations/voids
    • 2 Gal Of Finished Dilution / 10 Linear_Ft
  • Bath Traps
    • 1 - 2 Gal / Sq_Ft

POST-CONSTRUCTION CONVENTIONAL STRUCTURAL TREATMENTS

  • Shower Pan Drains
    • 1 - 4 Gal
  • Interior Treatment
    • 1 - 1.5 Gal / Sq_Ft
  • Exterior Perimeter Treatment
    • 2 Gal / 10 Linear_Ft / Ft_Of_Depth
  • Bath Traps
    • 1 - 2 Gal / Sq_Ft

HOLLOW BLOCK FOUNDATIONS/VOIDS

  • Hollow Block Foundations/voids
    • 2 Gal / 10 Linear_Ft

PRE-CONSTRUCTION TREATMENTS

  • Horizontal Treated Zones
    • 1 - 1.5 Gal / Sq_Ft
    • 1 Gal / Sq_Ft

WOODEN POSTS, POLES, SIGNS, LANDSCAPE ORNAMENTATION (OR OTHER WOODEN ITEMS)

  • Treatment At Time Of Installation
  • Treatment To Previous Installations
    • 2 Gal Of Finished Dilution / 10 Linear_Ft / Ft_Of_Depth

USE WITH OTHER PRODUCTS

  • Use With Borate-Based Termiticide Products
    • 2 Gal / 10 Linear_Ft / Ft_Of_Depth
  • Use With Non-Borate-Based Termiticide Products

FOAM APPLICATION

TERMITES ABOVE GROUND