Termidor 80 WG
DOT
WP/S&T
Applicators and other handlers must wear: Long-sleeved shirt and long pants Shoes plus socks Chemical-resistant gloves, such as barrier laminate, butyl rubber ≥ 14 mils, nitrile rubber ≥ 14 mils, neoprene rubber ≥ 14 mils, natural rubber* ≥ 14 mils, polyethylene, polyvinyl chloride (PVC) ≥ 14 mils, or viton ≥ 14 mils * Includes natural rubber blends and laminates When mixing and loading: a chemical-resistant apron When working in a non-ventilated space, including but not limited to basements and crawl spaces, all pesticide handlers must wear: A dust/mist filtering respirator which includes a NIOSH approved respirator with any N, R, P, or HE filter or NIOSH approval number prefix TC-84A When working in a non-ventilated space, including but not limited to basements and crawl spaces or when applying termiticide by rodding or sub-slab injection, all pesticide handlers must wear: Protective eyewear (goggles, a faceshield, or safety glasses with front, brow, and temple protection)
Not Applicable
Not Applicable
Store unused product in original container only, out of reach of children and animals.
Sara Title III
Hazardous Ingredient | Cas # | Percent | EHS TPQ | TRQ of Ingredient |
---|---|---|---|---|
[Fipronil] | 120068-37-3 | 80 | NOL | |
[Proprietary ingredients] | 20 | |||
[Fipronil] | 120068-37-3 | 80 | NOL | |
[Sodium-di-ethyl-hexyl-sulfosuccinate] | 577-11-7 | 1-5 | NOL |
[Fipronil] | |
Cas # | 120068-37-3 |
Percent | 80 |
EHS TPQ | NOL |
TRQ of Ingredient | |
[Proprietary ingredients] | |
Cas # | |
Percent | 20 |
EHS TPQ | |
TRQ of Ingredient | |
[Fipronil] | |
Cas # | 120068-37-3 |
Percent | 80 |
EHS TPQ | NOL |
TRQ of Ingredient | |
[Sodium-di-ethyl-hexyl-sulfosuccinate] | |
Cas # | 577-11-7 |
Percent | 1-5 |
EHS TPQ | NOL |
TRQ of Ingredient |
STATE RESTRICTIONS
State | Updated | Restriction Status |
---|---|---|
Alaska | 07/15/2020 | Not Restricted |
Alabama | 07/15/2020 | Not Restricted |
Arkansas | 07/15/2020 | Not Restricted |
Arizona | 07/15/2020 | Not Restricted |
Colorado | 07/15/2020 | Not Restricted |
Connecticut | 07/15/2020 | Not Restricted |
Delaware | 07/15/2020 | Not Restricted |
Florida | 07/15/2020 | Not Restricted |
Georgia | 07/15/2020 | Not Restricted |
Hawaii | 07/15/2020 | Not Restricted |
Iowa | 07/15/2020 | Not Restricted |
Idaho | 07/15/2020 | Not Restricted |
Illinois | 07/15/2020 | Not Restricted |
Indiana | 07/15/2020 | Not Restricted |
Kansas | 07/15/2020 | Not Restricted |
Kentucky | 07/15/2020 | Not Restricted |
Louisiana | 07/15/2020 | Not Restricted |
Massachusetts | 07/15/2020 | Not Restricted |
Maryland | 07/15/2020 | Not Restricted |
Maine | 07/15/2020 | Not Restricted |
Michigan | 07/15/2020 | Not Restricted |
Minnesota | 07/15/2020 | Not Restricted |
Missouri | 07/15/2020 | Not Restricted |
Mississippi | 07/15/2020 | Not Restricted |
Montana | 07/15/2020 | Not Restricted |
North Carolina | 07/15/2020 | Not Restricted |
North Dakota | 07/15/2020 | Not Restricted |
Nebraska | 07/15/2020 | Not Restricted |
New Hampshire | 07/15/2020 | Not Restricted |
New Jersey | 07/15/2020 | Not Restricted |
New Mexico | 07/15/2020 | Not Restricted |
Nevada | 07/15/2020 | Not Restricted |
Ohio | 07/15/2020 | Not Restricted |
Oklahoma | 07/15/2020 | Not Restricted |
Oregon | 07/15/2020 | Not Restricted |
Pennsylvania | 07/15/2020 | Not Restricted |
Rhode Island | 07/15/2020 | Not Restricted |
South Carolina | 07/15/2020 | Not Restricted |
South Dakota | 07/15/2020 | Not Restricted |
Tennessee | 07/15/2020 | Not Restricted |
Texas | 07/15/2020 | Not Restricted |
Utah | 07/15/2020 | Not Restricted |
Virginia | 07/15/2020 | Not Restricted |
Vermont | 07/15/2020 | Not Restricted |
Washington | 07/15/2020 | Not Restricted |
Wisconsin | 07/15/2020 | Not Restricted |
West Virginia | 07/15/2020 | Not Restricted |
Wyoming | 07/15/2020 | Not Restricted |
California | 07/15/2020 | Restricted |
New York | 07/15/2020 | Restricted |
PRODUCT APPLICATION
PRE-CONSTRUCTION TREATMENT
-
Concrete Slab - Horizontal Treated Zones
- 1.0 - 1.5 Gal / 10 Sq_Ft
-
Concrete Slab - Vertical Treated Zones
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
- 1.0 - 1.5 Gal / Sq_Ft
-
Crawl Spaces
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Hollow Block Foundations/voids
- 2 Gal / 10 Linear_Ft
-
Concrete Slab - Horizontal Treated Zones
- 1 - 1.5 Gal / 10 Sq_Ft
-
Concrete Slab - Vertical Treated Zones
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
- 1 Gal / Sq_Ft
-
Crawl Spaces
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Hollow Block Foundations/voids
- 2 Gal / 10 Linear_Ft
POST-CONSTRUCTION CONVENTIONAL
-
Concrete Slab On Ground - Exterior Perimeter
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Sub-Slab Injection - Vertical Drilling/injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Sub-Slab Injection - Horizontal Drilling/rodding/sub-Slab Injection From The Exterior Of The Foundation
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Concrete Slab On Ground - Exterior Perimeter
- 4 Gal / 10 Linear_Ft
-
Sub-Slab Injection - Vertical Drilling/injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Sub-Slab Injection - Horizontal Drilling/rodding/sub-Slab Injection From The Exterior Of The Foundation
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Bath Traps
- 1 - 4 Gal / Sq_Ft
-
Shower Pan Drains
- 4 Gal / Shower Pan Drain
BASEMENT STRUCTURES
-
Exterior Perimeter
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Inside Perimeter
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Interior Perimeter
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
HOLLOW BLOCK FOUNDATIONS/VOIDS
-
Hollow Block Foundations/voids
- 2 Gal / 10 Linear_Ft
-
Hollow Block Foundations/voids
- 2 Gal / 10 Linear_Ft
TREATMENT OF STRUCTURES WITH WELLS OR CISTERNS
-
Treatment Of Structures With Wells Or Cisterns
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
- 1 Gal / Cu_Ft Of Soil
-
Treatment Of Structures With Wells Or Cisterns
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
- 1 Gal / Cu_Ft Of Soil
PLENUM CONSTRUCTION
-
Plenum Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Plenum Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
POST-CONSTRUCTION
-
Exterior Perimeter Treatment - Concrete Slab On Ground Etc.
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter Treatment - Basement And Inaccessible Crawl Space Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter Treatment - Accessible Crawl Spaces
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter Treatment - Concrete Slab On Ground Etc.
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter Treatment - Basement And Inaccessible Crawl Space Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Exterior Perimeter Treatment - Accessible Crawl Spaces
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
SUB-SLAB INJECTION
-
Vertical Drilling/injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Horizontal Drilling/rodding/sub-Slab Injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Vertical Drilling/injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Horizontal Drilling/rodding/sub-Slab Injection
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
POST CONSTRUCTION
-
Localized Interior Treatment - Interior Concrete Floor
- 4 Gal / 10 Linear_Ft
-
Localized Interior Treatment - Hollow Block Foundations / Voids
- 2 Gal / 10 Linear_Ft
-
Localized Interior Treatment - Bath Traps
- 1 - 4 Gal Of Finished Dilution / Sq_Ft
-
Localized Interior Treatment - Shower Drains
- 1 - 4 Gal Finished Dilution / Shower Drain
-
Localized Interior Treatment - Interior Concrete Floor
- 4 Gal / 10 Linear_Ft
-
Localized Interior Treatment - Hollow Block Foundations / Voids
- 2 Gal / 10 Linear_Ft
-
Localized Interior Treatment - Bath Traps
- 1 - 4 Gal Of Finished Dilution / Sq_Ft
-
Localized Interior Treatment - Shower Drains
- 1 - 4 Gal Finished Dilution / Shower Drain
APPLICATIONS TO OUTSIDE SURFACES OF LISTED STRUCTURES AND INTO WALL VOIDS
-
Applications To Outside Surfaces Of Listed Structures And Into Wall Voids
- 0.06 % Dilution
-
Applications To Outside Surfaces Of Listed Structures And Into Wall Voids
- 0.06 % Dilution
APPLICATIONS TO PERIMETER OF LISTED STRUCTURES
-
Applications To Perimeter Of Listed Structures
- 0.06 % Dilution
- 2 Qt / 160 Linear_Ft
- 1.5 Gal / 1000 Sq_Ft
-
Applications To Perimeter Of Listed Structures
- 0.06 % Dilution
- 2 Qt / 160 Linear_Ft
- 1.5 Gal / 1000 Sq_Ft
POST CONSTRUCTION CONVENTIONAL
-
Bath Traps
- 1 - 4 Gal / Sq_Ft
-
Shower Drains
- 1 - 4 Gal Finished Spray Dilution / Shower Drain
-
Structures With French Drains And Sump Pumps
- 0.06 % Finished Dilution
- 0.09 % Finished Dilution
- 0.125 % Finished Dilution
POSTS, POLES, WOOD LANDSCAPE ORNAMENTATION
-
Posts, Poles, Wood Landscape Ornamentation
- 4 Gal / Linear_Ft / Ft_Of_Depth
ACCESSIBLE CRAWL SPACE CONSTRUCTION
-
Accessible Crawl Space Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
INACCESSIBLE CRAWL SPACE CONSTRUCTION
-
Inaccessible Crawl Space Construction
- 1 Gal / 10 Sq_Ft
FOAM APPLICATION
-
Foam Application
- 25 Gal
TERMITES ABOVE GROUND
-
Termites Above Ground
- 0.06 % Dilution
- 0.09 % Dilution
- 0.125 % Dilution
CRAWL SPACES
-
Accessible Crawl Space Construction
- 4 Gal / 10 Linear_Ft / Ft_Of_Depth
-
Inaccessible Crawl Space Construction
- 1.0 - 1.5 Gal / 10 Sq_Ft
STRUCTURES WITH ADJACENT WELLS/CISTERNS AND/OR OTHER WATER BODIES
-
Structures With Adjacent Wells/cisterns And/or Other Water Bodies
- 0.06 % Finished Dilution
- 0.09 % Finished Dilution
- 0.125 % Finished Dilution
USE WITH OTHER TERMITICIDE PRODUCTS
-
Use With Borate-Based Termiticide Products
- 0.06 % Finished Dilution
- 0.09 % Finished Dilution
- 0.125 % Finished Dilution
-
Use With Non-Borate-Based Termiticide Products
- 0.06 % Finished Dilution
- 0.09 % Finished Dilution
- 0.125 % Finished Dilution
PREVENTION AND/OR CONTROL OF WOOD INFESTING PESTS
-
Above Ground Termites And Carpenter Ants In Localized Areas
- 0.06 % Finished Dilution
-
Termites Or Carpenter Ants In Trees Or Nonstructural Wood Or Wood-To-Soil Contacts
- 1 Gal Finished Dilution / Ft_Of_Depth
- 4 Gal Finished Dilution / Ft_Of_Depth
-
Termite Carton Nests In Trees
- 1 Gal Finished Dilution
- 4 Gal Finished Dilution / 10 Linear_Ft
-
Drywood Termites And Wood-Infesting Beetles And Borers
- 0.06 % Finished Dilution
-
Carpenter Bees In Localized Areas
- 0.06 % Finished Dilution
APPLICATION TO EXTERIOR SURFACES OF STRUCTURES AND/OR INTO STRUCTURAL VOIDS
-
Application To Exterior Surfaces Of Structures And/or Into Structural Voids
- 0.06 % Finished Dilution
- 0.09 % Finished Dilution
- 0.125 % Finished Dilution
APPLICATION TO STRUCTURE FOUNDATION PERIMETERS
-
Application To Structure Foundation Perimeters
- 2 Qt / 160 Linear_Ft
- 1.5 Gal Finished Dilution / 1000 Sq_Ft
FOAM APPLICATIONS FOR PREVENTION AND/OR CONTROL OF TERMITES, WOOD-INFESTING PESTS AND GENERAL PEST CONTROL
-
Foam Applications For Prevention And/or Control Of Termites, Wood-Infesting Pests And General Pest Control
- 0.06 % Finished Dilution